.. _oil_enth_lin_sec: Oil linear enthalpy ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ The linear oil enthalpy model relates the enthalpy with temperature only, using the oil specific heat capacity. An example is given below: :: EOS OIL DENSITY CONSTANT 734.29d0 !kg/m3 ENTHALPY LINEAR_TEMP 1.d3 !c oil [J/kg/°C] VISCOSITY CONSTANT 0.987d-3 ! END The mathematical expression of the model is represented below: .. math:: h_{\mbox{oil}} =c_{\mbox{oil}} T, where: .. math:: \begin{split} &h_{\mbox{oil}} &= \mbox{oil Enthalpy [J]}\\ &c_{\mbox{oil}} &= \mbox{oil specific heat capacity [J/kg/°C]}\\ &T &= \mbox{temperature [°C]} \end{split} Units cannot be specified, therefore the oil specific heat must be entered in the units prescribed above.